VULCORE · V-100 1 POWER CONVERSION GRID INTERFACE 2 LIQUID COOLING PLANT 3 BATTERY · 520 kWh 4 RACK BAY · 3 TO 4 RACKS 12.19 M · 40 FT ISO HIGH CUBE A V-100 module. Its long side carries a chalk mural by neighborhood kids: a sun, clouds, a row of houses, trees, a school bus, a dog, a swing set and a water tower.
Power for the next decade of AI

AI needs power.Buildings already have it.

We build modules that run AI hardware on the spare power commercial buildings already have, and we set them in a parking space in weeks, not years.

Why Vulcore exists
AI can't wait for new power.Demand is growing faster than power plants and lines can be built.
Hiding in plain sight
~460 GW, trapped.Spare power behind the meters of 5.9 million U.S. commercial buildings. Our battery unlocks it.
The long game
Building America's largest AI network.Lasting infrastructure for where AI is going.
A product, not a project
One module at a time.Built on a line, set in weeks, built to stay. The box lasts; the chips inside change with the years.
Inside the V-100
An AI site
in every building.

Battery, liquid cooling and racks in one module. Put one behind every building with spare power and the AI people use runs next door: inference close to its users, on power already built. When the grid goes down, the building's critical circuits stay on.

  1. 1Power conversion and grid interface
  2. 2Liquid cooling plant
  3. 3Battery, 520 kWh
  4. 4Rack bay, 3 to 4 racks
Everyone is fighting over new power

We found the powerAmerica already built.

Every Vulcore site is a battery first. It runs the computers on power a building already has, pays the same rates as any business, and steps off the grid when the grid is stretched. No new plant, no new wires, no water main, no diesel. The next decade of AI, without a second grid.

AI needs power
3×

growth in U.S. data-center electricity demand by 2028.

AI needs proximity
5×

growth in inference capacity by 2030, pulling compute toward users and data.

The grid queue
5years

median wait to connect new power to the U.S. grid.

LBNL, Queued Up 2026
A Vulcore module
1–2weeks

to install behind a building's existing meter.

One Victor class module, built at three densities.

100 kW
continuous compute envelope
520 kWh
LFP battery · 4+ hr at full load
30%
thermal headroom above spec
DLC
direct liquid cooling for today's rack densities
What runs here
Serving a modelFine-tuningRendering and videoSimulationOvernight batch jobs

Three or four racks of work, close to the people it serves.

Three sizes

Every Victor is the same manufactured design, built once and deployed everywhere. Add modules to grow a site. Add sites to grow the fleet.

30 kW · 150 kWhAir
COOLING BATTERY 42U PCS
3.05 m long · 10 ft skid

V-30

Compact. Edge inference and lighter density.

  • Compute envelope30 kW
  • Battery, usable150 kWh LFP
  • CoolingAir
  • Racks1 × 42U
  • Form factor10 ft skid
  • Service480 V 3φ · ~200 A spare
60 kW · 300 kWhAir or liquid
COOLING BATTERY 42U 42U PCS
6.06 m long · 20 ft ISO

V-60

Mid-tier. Standard inference density on a smaller site.

  • Compute envelope60 kW
  • Battery, usable300 kWh LFP
  • CoolingAir or liquid
  • Racks2 × 42U
  • Form factor20 ft ISO
  • Service480 V 3φ · ~200 A spare
100 kW · 520 kWhDirect liquid
COOLING BATTERY 42U 42U 42U PCS
12.19 m long · 40 ft ISO

V-100

Full capacity. The mainstream module, opened up above.

  • Compute envelope100 kW
  • Battery, usable520 kWh LFP
  • CoolingDirect liquid
  • Racks3 to 4 × 42U
  • Form factor40 ft ISO
  • Service480 V 3φ · 250 A floor
320A
Which Victor fits

A V-100 fits.

320 A at 480 V three-phase is about 266 kVA of headroom, 70 A over the V-100 floor. The module draws 95 kW on average and 110 kW at full load; the battery carries the peaks.

Ask about this fit

V-100RThe ruggedized Victor, for federal and defense sites. Defense →

How it works · four steps

From signature to energized racks.

The module is equipment on your site, like a generator or a battery cabinet. Not a facility, not a rezoning, not a new use.

  1. Site

    01 · Screened · contracted

    A qualifying commercial property with spare electrical capacity. We screen it, contract it, and handle deployment with the property host.

  2. Module

    02 · One to two weeks

    A standardized module arrives with battery, cooling, racks, networking, and controls. It installs behind the existing meter in one to two weeks. Service looks like commercial equipment, not data center operations.

  3. The battery

    03 · Limit · events · revenue

    Three jobs at once. It keeps the module inside the site's electrical limit, carries the racks through grid events, and earns when the grid needs flexibility. That revenue helps lower the cost of the site.

  4. Your racks

    04 · Power and place

    You install your hardware, or we receive it for you. Your hardware. Your customers. Your software. Your GPU-hour. We bill for power and place.

Bring your own hardware

We energize your hardware.
We never touch its software.

If it fits the envelope, it racks.

The module sets a power, cooling, and mechanical envelope. If your hardware fits it, it racks. Standard eight-GPU servers rack directly. You own the servers and the software. We don't sell compute.

NVIDIAAMDx86ArmCustom ASICs

Locked, monitored, screened.

A locked steel enclosure with one lockable utility tie-in, monitored around the clock. Every site is screened before we contract it.

Who runs what

Your hardware, your images, your keys. Power, temperature, uptime, and clean-energy share for your Scope 2 reporting come to you. Site economics stay between us and the host.

Supply chain: every part screened against federal foreign-entity (FEOC) restrictions, and control firmware with documented provenance.
Built for inference

A serving cluster at one site is a network at a hundred.

Each module is a complete serving cluster.

Fast local storage in every module: weights download once, then serve from the box. Fast interconnect inside each node and across the racks. Power, cooling and network live in the unit.

Fiber that rides the battery.

Two carriers, automatic failover, and the module's network gear on its battery. When the grid dips, the racks keep serving and the uptime line barely moves.

Add sites to grow the network.

The same module, the same install and the same software at every site: VNDX (Vulcore Network Dispatch Index), our software platform, runs each one from its controls to its console. The second site is a copy of the first, and so is the hundredth. Capacity rolls up into one contract, and the batteries roll up into a fleet the grid pays to call on, which lowers the cost of power at every site.

Production inference at any replica count.

Batch workloads and fine-tuning within a module, production serving across the fleet, one VNDX console scoped to your capacity. We bill for power and place.

Reserve capacity
VNDX partner console
Compute partners

Compute in weeks, on power the building already has.

Put your GPUs to work now. If a chip fits the module, it racks, and it stays yours end to end: hardware, software, keys, GPU-hour.

Hardware that sits idle loses more each month than it costs to energize it here. Early partners get site priority, input on configuration, and pricing that rewards going first.

Reserve capacity
Property hosts

Own a building with spare electrical capacity?

Let's talk. We pay rent for the capacity you don't use and for about one parking space, at zero cost to you. We finance, install, insure, and operate the module, and when the grid goes down, your building's critical circuits stay on.

Running AI of your own? The same module can power your servers, on your property, behind your fence.

Talk to us about your site
Questions · Water · Power · Safety

Hard questions. Plain answers.

What does Vulcore do?

We build distributed AI infrastructure: a network of battery-backed AI compute sites on the spare electrical capacity commercial buildings already have. Each site is a Victor module: a battery, cooling and racks of AI servers in one box, set behind a building's meter in weeks.

Where does the power come from?

From room the building already has. A commercial building's electrical service is sized for its busiest moment, and most of the time much of it goes unused. A Victor module uses that spare room. Its battery fills up when the building is quiet and carries the module when the building is busy. The building never draws more than its service was built for. That's what we mean by firming: making capacity that already exists steady enough to rely on. No bigger connection, no new transformer, no new line.

What happens when the power shortage eases?

Prices for capacity will come down as new plants and lines get built, and we plan for that. A Victor module needs no land, no new building, no substation and no new line, so it costs less per kilowatt to deliver than a new campus, even after power catches up. And AI keeps moving closer to the people who use it, into the buildings where they live and work, long after the grid catches up. The case for a module doesn't depend on the shortage lasting.

Does Vulcore use water?

Not the way data centers do. No cooling towers, no water main, no new water line. On the hottest summer afternoons, a Victor module sprays a light mist on its cooler from an ordinary garden hose. It uses less than half the flow of a bathroom faucet. A large data center can use up to 5 million gallons of water a day. That's more than a Victor module uses in 200 years. A garden hose, not a water main.

Is a Vulcore module a data center?

No. It's a battery and a few racks of computers in one steel box, placed at a building that already has more electricity than it uses. It draws about a tenth of a megawatt, about what a mid-size office building uses and hundreds of times less than the big campuses that need their own power plants and power lines. It needs no new power plant, no new wires, no water main and no diesel, and it pays the same electricity rates as any business.

Does Vulcore get tax breaks or special electricity rates?

No. A module pays the same electricity rates as the building it sits next to, and we don't ask for tax breaks or incentives to put one in.

Does a module raise anyone's electricity bill?

No. A module runs on power the building's wiring can already deliver, so the utility builds nothing new and there's nothing new for anyone to pay for. It draws a steady amount day and night, and steady customers are the cheapest kind for a utility to serve, which helps hold everyone's rates down. When the grid is stretched, the battery takes over and the module all but stops drawing from the grid for a few hours.

Is it good or bad for the grid?

It's built to help. The grid has to match supply and demand every second to hold 60 cycles, and too little demand strains it too. A Victor module's battery soaks up power when there's extra and steps off the grid when there isn't enough. It also gets more out of wires that are already built: commercial buildings use well under half of their electrical service on average, and a module puts that idle capacity to work instead of asking for new lines. When the grid goes down, the building's critical circuits stay on.

Is the battery safe?

Victor modules use lithium iron phosphate, the battery chemistry utilities rely on for grid storage. It's far more stable than the batteries in phones and laptops. A fire-rated wall separates the battery from the servers, gas and heat sensors are watched around the clock, vents release battery gas safely, and the module stands outdoors at the distance fire code sets from the building. An independent lab tests and certifies every module before it ships. We install to national fire code, and the local fire department reviews every site before it turns on.

Is this a good way to build AI?

We think it's the best one on offer. AI is getting built either way; the question is what it costs everyone else. Every Vulcore site is a battery first. It runs the computers on power a building already has, so no one builds a new plant or a new line to serve it. It pays the same electricity rates as any business, with no tax breaks. When the grid is stretched, the battery steps the module off the grid for a few hours, and when the power goes out, it keeps the building's critical circuits on. It uses no water main and no diesel. And it stays in town: rent to a local building owner, property tax paid locally, local electricians, and data that stays near the people it serves. We also know who we host. Every customer is screened and held to published rules on what can run at our sites, and every machine stays in the United States.

All questions

Tell us what
you need energized.

Capacity on the first sites is limited, so tell us the megawatts, the date you need them, and the hardware you already own.

  1. 01A person replies within two business days.
  2. 02We come back with a site and a rate.
  3. 03Your hardware is racked and energized in weeks.

We use these details to reply and keep a record of our conversation. Privacy policy.

Received

Received. We reply within two business days about capacity and timeline.

No new land. No new wires. No diesel. No water main. Power America already built.